FreshDuct cleans and inspects the flue systems and chimneys behind Rinnai gas log fires across Melbourne. Gas-carrying work is a licensed trade in Victoria, and we are explicit about where our scope ends.
Gas fire in an old masonry chimney? The chimney is ours. The gas appliance is a gasfitter’s.
Rinnai produces a substantial range of gas log fires in Australia, including freestanding and built-in models such as the GF750 and the SS850 inbuilt, and the 1250 rated at 8.4 kW for larger open-plan living areas. They are common appliances in Melbourne homes and we are asked about them constantly, so it is worth being precise about what FreshDuct does and does not do.
In Victoria, work on gas appliances is a legally restricted trade regulated by Energy Safe Victoria. It must be carried out by a licensed gasfitter, and it is illegal to service or repair a gas fire yourself or to have an unlicensed person do it. That restriction covers the burner, the injector, the pilot and flame-failure device, the gas control valve and the connection. FreshDuct does not touch any of it, and we will not pretend otherwise to win a job.
What we do is the flue and chimney side, which is substantial and genuinely ours. A great many Rinnai gas fires in Melbourne are installed into an existing masonry fireplace, venting up an old brick chimney that was built for an open wood fire. That chimney is our work: its condition, whether it is clear, whether it is lined, whether the crown and flashing are sound, and whether it is capable of safely carrying the products of combustion from the appliance now connected to it.
That distinction matters more than it sounds. A gas appliance can be in perfect order and the installation still be unsafe because the chimney above it is blocked, unlined, deteriorated or shared with another flue. Carbon monoxide is colourless and odourless, and the flue is what keeps it outside the house. Getting the chimney properly inspected is not a lesser job than servicing the appliance — it is the other half of the same safety question.
Manufacturer published facts only. No model specifications we could not source.
The flue and chimney side of the system – which is where a great many faults actually sit.
Where a gas fire has been installed into an existing fireplace, the original brick chimney is carrying the combustion products. We inspect it internally where access allows, checking for obstruction, debris, deterioration of the internal brickwork and whether the flue is lined. An old chimney is not automatically suitable for a gas appliance.
A blocked flue on a gas appliance is a carbon monoxide risk rather than merely a smoking nuisance, because gas combustion products are largely invisible. Birds, possums, fallen mortar and accumulated debris all obstruct old flues. We inspect, photograph and clear obstruction as chimney work.
The top of the chimney determines whether the flue stays dry and whether it can discharge properly. Cracked crowns, failed flashing and damaged or missing terminals let water in and can interfere with discharge. We assess from the roof where access is safe and photograph what we find.
A wide unlined masonry flue may be poorly suited to a gas appliance producing a much smaller volume of cooler flue gas. We inspect and report on the flue condition and size, and where lining is the appropriate remedy we quote that as chimney work.
The burner, injector, pilot, flame-failure device, gas control and the gas connection are licensed gasfitting work under Energy Safe Victoria. FreshDuct arranges a licensed gasfitter for that portion, in the same booking as the flue work.
FreshDuct recommends an annual flue and chimney inspection for any flued gas appliance, alongside the appliance service that a licensed gasfitter should be carrying out. Two different trades, both worth doing, and both annually.
Real FreshDuct chimney photography from Melbourne jobs. Captions describe the work only, not any particular brand of appliance.




FreshDuct inspects, sweeps and repairs the chimney and flue system: internal flue condition, obstruction and debris removal, liner assessment, crown, flashing, terminal and masonry condition. All of it photographed, with a written report you can hand to your gasfitter.
The gas appliance itself — burner, injector, pilot, flame-failure device, control valve and connection — must be serviced by a licensed gasfitter under Energy Safe Victoria, and FreshDuct arranges one for you. FreshDuct also has no affiliation with Rinnai and is not its agent or authorised repairer; appliance warranty matters go to Rinnai or your original installer.
Book a Flue InspectionWe inspect and service chimneys serving gas fires across metropolitan Melbourne. The installations that most need it are in the period housing of the inner suburbs — Fitzroy, Carlton, Collingwood, Northcote, Brunswick, Kew, Hawthorn, Malvern, Brighton and Williamstown — where a gas fire has been fitted into a Victorian or Edwardian fireplace.
Those chimneys are typically unlined, often over a century old, and frequently share a stack with other flues from other rooms or, in terraces, other properties. That combination is exactly why an annual flue inspection on a gas appliance is worth doing, and why we photograph the flue interior rather than reporting a verbal impression.
The chimney side, done thoroughly and documented.
Existing masonry chimney, lined flue, or a purpose-built kit.
Flue interior examined and photographed where access allows.
Debris, nesting material and fallen mortar identified and cleared.
Crown, flashing, terminal and masonry checked from the roof where safe.
Photographed condition report you can give to your gasfitter.
Appliance servicing by a licensed gasfitter we arrange.
Verified 5-star reviews from across FreshDuct’s chimney, fireplace, duct, heating and insulation services. These are company-wide reviews from our Melbourne customer base — not reviews of any particular appliance brand.
“Allen provided exceptional service — friendly, professional and went above and beyond.”
“Highly impressed with the professionalism and efficiency. On time, and no mess left behind.”
“Exceeded my expectations. Knowledgeable, meticulous and respectful of our home.”
“So glad I chose FreshDuct. Knowledgeable team and the whole process was smooth from start to finish.”
“Quick, efficient and professional — we could immediately feel the difference.”
“The technician arrived on time and was incredibly thorough — the difference at home is obvious.”
What a flued gas appliance needs from the chimney side.
Yes, through a licensed gasfitter we arrange. In Victoria, servicing or repairing a gas appliance is legally restricted to a licensed gasfitter regulated by Energy Safe Victoria. What FreshDuct does directly is the chimney and flue: internal inspection, obstruction removal, liner assessment and masonry condition, all photographed and reported.
Because the flue is what carries the combustion products out of the house, and carbon monoxide is colourless and odourless. A blocked, deteriorated or unlined chimney can make a perfectly good appliance unsafe. With a wood fire a flue problem announces itself as smoke; with gas it does not announce itself at all.
No. FreshDuct is an independent chimney and flue service company with no affiliation to Rinnai or its dealers. We service the chimney and flue system, and arrange a licensed gasfitter for the appliance. Warranty matters go to Rinnai.
It depends on the flue size, its condition and the appliance. A wide unlined masonry flue built for an open wood fire may be poorly suited to the much smaller volume of cooler gas produced by a gas appliance. We inspect and photograph the flue interior and give you a straight assessment to take to your installer.
FreshDuct recommends annually for any flued gas appliance, alongside the appliance service a licensed gasfitter should be carrying out. They are two different trades doing two different jobs, and both matter. An annual chimney inspection is inexpensive relative to what it is protecting against.
Chimney and flue inspected, photographed and reported — the half of gas fire safety that a gasfitter does not cover.
Tell us the model and how the fire is vented.