Some people are using the FreshDuct name and pretending to be us to scam customers. Please don't fall for it. We are the only genuine FreshDuct, operating in Melbourne, Sydney, Adelaide and Perth. Only deal with us through freshduct.com.au, or call us directly on 04 3191 8137 or 0480 004 051. We are taking legal action against these impostors. Thank you.

Independent Service Provider Open-Fronted Gas FiresChimney Specialists

Real Flame Gas Log Fire Flue Service in Melbourne

FreshDuct inspects and services the chimneys behind Real Flame gas log fires across Melbourne — particularly the open-fronted units venting into original masonry fireplaces.

Open-fronted gas fire in a period fireplace? The chimney is doing all the safety work.

An open-fronted gas fire shares its combustion space with your living room. Everything that keeps the products of combustion out of that room is happening in the chimney above it.
Real Flame Flue Servicing

Open-Fronted Gas Fires and the Chimney Above Them

Real Flame designs and manufactures fireplace heaters and its products incorporate safety devices including flame failure and oxygen depletion systems. Those devices are meaningful protections and they are part of why open-fronted gas fires can be used safely. They are also appliance components, which means they are serviced by a licensed gasfitter, which FreshDuct arranges.

FreshDuct works on the chimney, and on an open-fronted gas fire installed into an existing masonry fireplace the chimney carries an unusual amount of responsibility. Unlike a sealed glass-fronted unit, which draws combustion air from outside and vents through a dedicated flue, an open-fronted appliance is open to the room. Its combustion products go up the chimney because the chimney draws them, and for no other reason.

That places real requirements on the chimney. It has to be clear. It has to draw adequately with the much smaller, cooler gas volume it now carries instead of the hot high-volume plume an open wood fire produced. It should not be shared in a way that lets products enter another room. And it needs to be structurally sound, because deterioration inside an old flue can open paths into the building fabric.

The oxygen depletion sensor is designed to shut the appliance down if oxygen in the room falls, which is exactly the protection an open-fronted appliance needs. But it is a last line of defence, and it works best in a system where the chimney is doing its job in the first place. Getting the chimney properly inspected is what keeps that safety device as a backstop rather than as the thing standing between you and a problem.

Real Flame Facts

What We Verified About Real Flame

Manufacturer published facts only. No model specifications we could not source.

Design and manufactureReal Flame designs and manufactures fireplace heaters
Flame failureReal Flame products incorporate flame failure safety devices
Oxygen depletionReal Flame products incorporate oxygen depletion safety systems
Chimney dependentOpen-fronted gas fires rely on the chimney to carry combustion products
Common Faults

What We Check Above an Open-Fronted Gas Fire

The chimney requirements that an open-fronted appliance actually depends on.

Draught with a much smaller gas volume

A chimney built for an open wood fire was sized for a large, hot plume. A gas fire produces a far smaller volume of cooler gas, which draws far less strongly up the same wide shaft. We assess whether the flue is capable of reliably carrying that lesser volume, and report if lining to a suitable size is the sensible remedy.

Obstruction on a fire that is open to the room

On an open-fronted appliance, anything obstructing the chimney pushes combustion products directly into the living space. Nests, debris and fallen mortar all do it. We inspect specifically for obstruction, photograph it, and clear it as chimney work.

Internal flue condition and shared stacks

Old chimneys deteriorate internally and many Melbourne stacks carry several flues from different rooms, or in terraces from different properties. Breaches between flues in a shared stack can let products enter another room entirely. We inspect internally where access allows and report what we can and cannot see.

Terminal, crown and rain ingress

Water entering the top of a chimney accelerates internal deterioration and can affect draught. We check the crown, flashing and terminal from the roof where access is safe, and photograph the condition of the stack.

The appliance and its safety devices

Flame failure devices, oxygen depletion sensors, burners, injectors and pilots are appliance components. Testing and servicing them is licensed gasfitting work under Energy Safe Victoria, so FreshDuct arranges a licensed gasfitter for it in the same booking.

Inspection interval

FreshDuct recommends an annual chimney inspection for any open-fronted gas appliance, alongside the appliance service a licensed gasfitter should carry out. On an open-fronted installation the chimney is not a secondary consideration — it is the primary means of keeping combustion products out of the room.

Real FreshDuct Work

Chimney Inspection and Repair Work

Real FreshDuct chimney photography from Melbourne jobs. Captions describe the work only, not any particular brand of appliance.

An unlined masonry chimney flue photographed from inside.
An unlined masonry chimney flue photographed from inside.
Repointing work on an older Melbourne chimney stack.
Repointing work on an older Melbourne chimney stack.
A chimney terminal inspected from the roof.
A chimney terminal inspected from the roof.
Masonry repointing work on a Melbourne chimney
Our Scope

Chimney Work, With the Gas Line Clearly Drawn

FreshDuct inspects the chimney internally, checks for obstruction and clears it, assesses internal masonry condition and flue sizing, examines the crown, flashing and terminal from the roof where safe, and provides a photographed written report. Lining, repointing and repair are our work and quoted as such.

The appliance, including its flame failure and oxygen depletion devices, is licensed gasfitting work under Energy Safe Victoria, done by a licensed gasfitter we arrange. FreshDuct has no affiliation with Real Flame and is not its agent or repairer; warranty goes to Real Flame, and appliance servicing is done by a licensed gasfitter we arrange.

Book a Chimney Inspection
Service Area

Open-Fronted Gas Fire Chimney Work Across Melbourne

We inspect chimneys serving open-fronted gas fires throughout metropolitan Melbourne, and the installations cluster in period housing: Fitzroy, Carlton, Collingwood, Northcote, Brunswick, Kew, Hawthorn, Malvern, Brighton, Williamstown, Essendon and the inner-city terraces.

Terrace and semi-detached housing deserves particular mention, because those chimneys often share a stack with a neighbouring property. A breach inside a shared stack can carry combustion products somewhere entirely unintended, which is one of the more serious things a proper internal inspection can find and one of the least likely to be noticed otherwise.

Melbourne CBDCarltonFitzroyBrunswickNorthcoteIvanhoeKewHawthornCamberwellBalwynDoncasterRingwoodCroydonLilydaleHealesvilleElthamWarrandyteGreensboroughEssendonWilliamstownBrightonMalvernGlen IrisMount WaverleyBerwickMorningtonMacedon RangesYarra ValleyDandenong Ranges
How We Work

Our Open-Fronted Gas Fire Chimney Process

A genuine internal inspection, not a look up from the hearth.

1

Confirm the Appliance Type

Open-fronted into a chimney, or a sealed glass-fronted unit.

2

Inspect Internally

Flue interior examined and photographed as far as access allows.

3

Check for Obstruction

Nests, debris and fallen mortar identified and cleared.

4

Assess Flue Sizing

Whether the shaft suits the much smaller gas volume it now carries.

5

Examine the Stack

Crown, flashing, terminal and shared-flue risk assessed from the roof.

6

Photographed Report

Written findings you can give your gasfitter or installer.

5-Star Rated

What FreshDuct Customers Say

Verified 5-star reviews from across FreshDuct’s chimney, fireplace, duct, heating and insulation services. These are company-wide reviews from our Melbourne customer base — not reviews of any particular appliance brand.

★★★★★

“Allen provided exceptional service — friendly, professional and went above and beyond.”

J
Jane
Wantirna South, VIC
Verified
★★★★★

“Highly impressed with the professionalism and efficiency. On time, and no mess left behind.”

R
Ralph
Brighton, VIC
Verified
★★★★★

“Exceeded my expectations. Knowledgeable, meticulous and respectful of our home.”

M
Marc
Cranbourne East, VIC
Verified
★★★★★

“So glad I chose FreshDuct. Knowledgeable team and the whole process was smooth from start to finish.”

D
David
Williams Landing, VIC
Verified
★★★★★

“Quick, efficient and professional — we could immediately feel the difference.”

J
Juliette
Croydon, VIC
Verified
★★★★★

“The technician arrived on time and was incredibly thorough — the difference at home is obvious.”

S
Verified Customer
South Morang, VIC
Verified
FAQs

Real Flame Gas Fire Questions

What is an oxygen depletion sensor and does it mean the chimney matters less?

It is a safety device that shuts the appliance down if oxygen in the room falls, and it is an important protection on an open-fronted fire. It does not make the chimney less important. It is a last line of defence, and it works best in an installation where the chimney is reliably carrying combustion products out in the first place.

Can an old open-fire chimney safely serve a gas fire?

Often yes, but it should be inspected rather than assumed. The chimney was sized for a large hot plume and now carries a much smaller, cooler volume, which draws far less strongly. We inspect internally, assess sizing and condition and give you a written photographed report rather than a reassurance.

My house is a terrace. Does a shared chimney stack matter?

Yes, and it is one of the more serious things an internal inspection can find. Old stacks frequently carry several flues, sometimes from neighbouring properties, and a breach between them can carry combustion products into another room or another home. It is not visible from the hearth or the roof.

Is FreshDuct an authorised Real Flame service agent?

No. FreshDuct is an independent chimney and flue service company with no affiliation to Real Flame or its dealers. We inspect, clear and repair chimneys and flues, and arrange a licensed gasfitter for the appliance. Warranty matters go to Real Flame.

How far up can you actually inspect?

That depends on the installation and the access available, and we tell you exactly how far we got. Where a fire or its surround prevents access to the flue above, we say so in the report rather than implying the whole shaft was inspected. A report that overstates its coverage is worse than no report.

Independent service provider. FreshDuct is not affiliated with, authorised by, endorsed by or an agent of Real Flame or its distributors. Real Flame and all other product names mentioned are the property of their respective owners, and are used here only to describe the appliances FreshDuct cleans, inspects and services. For warranty work, replacement parts or anything that must be done by the manufacturer, contact Real Flame or your original supplier directly.

Book an Open-Fronted Gas Fire Chimney Inspection

Internal inspection, obstruction clearing and a photographed report on the chimney your gas fire depends on.

Request your free chimney inspection quote

Tell us if the fire is open-fronted or a sealed glass-fronted unit.